Using this setting you specify whether the device forwards serial data in binary format and therefore without CR/LF adjustment (CR/LF = carriage return/line feed). Since binary mode can cause problems with some serial remote stations, you should maintain the default Auto.
- Telnet path:
- Possible values:
- Auto: For data transmission, the COM-port server initially switches to ASCII mode; however, it uses telnet options to negotiate with the remote station whether it can switch to binary mode.
- Yes: For data transmission, the COM port server switches to binary mode and does not use the telnet options to negotiate this with the remote station.
- No: For data transmission, the COM port server switches to ASCII mode and does not use the telnet options to negotiate this with the remote station.
- Default:
- Auto