Config-and-script

This option activates the automatic loading of configuration and/or script files from a connected USB medium.

Note: This option is set to "inactive" in the Security Settings Wizard or the Basic Settings Wizard.
Note: A device can be fed with an undesirable configuration by resetting it to its factory settings and inserting a prepared USB data media. To prevent this you have to deactivated the reset switch.
SNMP ID:
2.56.2 
Console path:
Setup > Autoload
Possible values:
Idle
Automatic loading of configuration and/or script files is deactivated.
Operating
Automatic loading of configuration and/or script files is activated. When a USB medium is mounted, a suitable configuration and/or script file us uploaded to the device. The USB medium is mounted when it is plugged into the USB port on the device, or when it is restarted.
If-unconfigured
Automatic loading of configuration and/or script files is only activated when the device has its factory settings. A configuration reset can be used to return the device to its factory settings at any time.
Default:
If-unconfigured