This option activates the automatic loading of configuration and/or script files from a connected USB medium. Save the required configuration and/or script files in the "Config" directory located in the root directory of the connected USB media.
Note: This option is set to "inactive" in the Security Settings Wizard or the Basic Settings Wizard.
Note: A device can be fed with an undesirable configuration by resetting it to its factory settings and inserting a prepared USB data media. To prevent this you have to deactivated the reset switch.
- SNMP ID:
- 2.60.56.2
- Console path:
- Setup > Autoload > USB
- Possible values:
- Inactive
- Automatic loading of loader and/or firmware files is deactivated.
- Operating
- Automatic loading of configuration and/or script files is activated. When a USB medium is mounted, a suitable configuration and/or script file us uploaded to the device. The USB medium is mounted when it is plugged into the USB port on the device, or when it is restarted.
- If-unconfigured
- Automatic loading of configuration and/or script files is only activated when the device has its factory settings. A configuration reset can be used to return the device to its factory settings at any time.
- Default:
- If-unconfigured