Modifying a Public Spot user

Modify one or more Public Spot users simply by entering the following URL:

http://<device-URL>/cmdpbspotuser/...?action=editpbspotuser&parameter1=value1&parameter2=value2&...

The following parameters are available:

pbspotuser
Name of the Public Spot user
Specify multiple users in the form &=pbspotuser=<User1>+<User2>+.... If the wizard cannot find the specified user, you have the option to search for a user. After making your changes, accept these and print them out if necessary.
expirytype
Combined output of expiry type and, if applicable, the validity period of the voucher.
Specify this parameter as follows:
&expirytype=<Value1>+validper=<Value2>
The parameter values have the following meaning:
  • Value1: Expiry type. Possible values are absolute, relative, both, and none.
  • Value2: Time of the voucher's expiry if expirytype has the value both. In this case, you use validper to specify the voucher's maximum validity period in days for the absolute expiry type. For all other expiry types, the parameter validper is not set.
If a parameter is omitted or set with incorrect values the wizard will apply the default values.
unit
Access time
Specify this parameter as follows:
&unit=<Value1>+runtime=<Value2>
The parameter values have the following meaning:
  • Value1: LIfetime units. Possible values are: Minute, hour, day
  • Value2: Duration
timebudget
Time budget
If this parameter is omitted, the wizard uses the default value.
volumebudget
Volume budget
If this parameter is omitted, the wizard uses the default value.
print
Automatic print-out of the voucher.
If this parameter is omitted, the wizard displays a button. Use this to print out the voucher.
bandwidthprof
Bandwidth profile
With this parameter you assign a pre-defined bandwidth profile to a Public Spot user. Enter the valid value for this parameter as the line number of an existing profile name under Setup > Public Spot module > Add user wizard > Bandwidth profiles, such as
&bandwidthprof=1
to index the first entry in the table.
If this parameter is missing or the line number is invalid (for example, the table is empty), the wizard does not limit the bandwidth.
Note: If the Public Spot administration contains no default values to replace missing parameters, the wizard opens a dialog. Enter the missing values here.

www.lancom-systems.com

LANCOM Systems GmbH | A Rohde & Schwarz Company | Adenauerstr. 20/B2 | 52146 Wuerselen | Germany | E‑Mail info@lancom.de

LANCOM Logo